The sculptured autologous orbital floor implant showed an excellent fit in vivo.
Orbital floor implant surgery cost. 3 of these patients only 30 with pure blowout fractures were included in our study. Some surgeons say that 50 percent involvement of the orbital floor or wall is an indication for surgery dr. 1 clinical diagnosis of an orbital floor defect. Repair of an orbital floor fracture by the transconjunctival technique and the use of porous polyethylene implant stabilized with cyanoacrylate glue has many advantages including simplicity of the technique excellent structural support shorter operative time and cost effectiveness.
Insertion of a titanium implant to the orbital floor. The tangible mold was subsequently used during surgery to sculpture an individualized autologous orbital floor implant. The implant edges can be delicately shaped and feathered for a smooth transition from the implant to the patient s. To the defect area at the time of surgery.
No results liu jk gotfried on cole cd dougherty wr couldwell wt medpor porous polyethylene implant for cranioplasty and skull base reconstruction neurosurgery april 2004. The orbital floor is located between the orbit 1 and the maxillary sinus 2. Implants designed using ct scan data to approximate the anatomy of the orbital floor and medial wall. I just had an orbital blowout over 95 of my right orbital floor was fractured and they replaced with the bone with an implant.
Schematic sectional view of a skull. The surgery itself was about 600 with the hospital stay and additional expenses i paid around 3 000 after insurance paid their part. He prefers to measure the size of the fracture in two dimensions and the degree of fragment displacement on ct scan. Pseudoelastic shape memory alloys are often used in medical applications.
The superior non porous barrier of the implants helps prevent tissue ingrowth along the aspect of the globe. Virtual reconstruction of the orbital floor and the resulting mold enhanced the overall accuracy and efficiency of the surgical procedure. They fulfilled the following inclusion criteria. In the department of maxillofacial surgery of the federico ii university of naples italy between 2005 and 2007 we observed 44 unilateral fractures of the orbital floor pure and impure.